Infectious Diseases | We have a special suite of tests for our international customers where CE marking isn?t an issue. |
|
| |
|
| CEAC |
 |
Carcinoembryonic Antigen (CEA) is a test often used for detecting and monitoring certain types of cancer. If CEA levels are above normal before surgery, chemotherapy or radiotherapy, their return to normal within 6 weeks usually indicates successful treatment. Persistent high levels can suggest residual or recurrent tumour tissue.
|
|
| |
|
| HBANBSC |
 |
The complex antigen found on the surface of Hepatitis B virus (HBV) is called HBsAg. HBsAg has four principal subtypes: adw, ayw, adr and ayr. Because of antigenic heterogeneity of the determinant, there are 10 major serotypes of Hepatitis B virus. This test detects them all.
The test uses a combination of monoclonal and polyclonal antibodies to selectively detect elevated levels of HBsAg in whole blood, serum or plasma. - Attractive cassette format
- Best international prices
- Relative Sensitivity: >99.0%
- Relative Specificity: 99.7%
- Accuracy: 99.8%
- High performance immunoassay technology
- Best technology with full technical support
|
|
| |
|
| HBANSC |
 |
The complex antigen found on the surface of Hepatitis B virus (HBV) is called HBsAg. HBsAg has four principal subtypes: adw, ayw, adr and ayr. Because of antigenic heterogeneity of the determinant, there are 10 major serotypes of Hepatitis B virus. This test detects them all.
The test uses a combination of monoclonal and polyclonal antibodies to selectively detect elevated levels of HBsAg in serum or plasma. - Attractive cassette format
- Best international prices
- Relative Sensitivity: >99.0%
- Relative Specificity: 98.7%
- Accuracy: 99.5%
- Serum / plasma specific
- High performance immunoassay technology
- Best technology with full technical support
|
|
| |
|
| HBCAB |
 |
The HBcAb One Step Hepatitis B core antibody Test Device (Serum/Plasma) is a rapid test to qualitatively detect the presence of HBcAb in serum or plasma specimen. The test utilizes a combination of monoclonal antibodies and antigen to selectively detect elevated levels of HBcAb in serum or plasma.
- Attractive cassette format
- Best international prices
- Relative Sensitivity: 96.3%
- Relative Specificity: 96.8%
- Accuracy: 96.4%
- Serum / plasma specific
- High performance immunoassay technology
- Best technology with full technical support
|
|
| |
|
| HBSABSS |
 |
The HBsAb Hepatitis B Surface Antibody Rapid Test Strip (Whole Blood/Serum/Plasma) is an easy to use, inexpensive rapid test strip to qualitatively detect the presence of HBsAb in whole blood, serum or plasma specimen. The test utilizes a double antigen sandwich system to detect as low as 10 mIU/mL of HBsAb in whole blood, serum or plasma.
- Lowest cost strip format
- Best international prices
- Relative Sensitivity: 99.6%
- Relative Specificity: 99.4%
- Accuracy: 99.5%
- Serum / plasma specific
- High performance immunoassay technology
- Best technology with full technical support
|
|
| |
|
| HBSAGSS |
 |
The complex antigen found on the surface of Hepatitis B virus (HBV) is called HBsAg. HBsAg has four principal subtypes: adw, ayw, adr and ayr. Because of antigenic heterogeneity of the determinant, there are 10 major serotypes of Hepatitis B virus. This test detects them all.
The test uses a combination of monoclonal and polyclonal antibodies to selectively detect elevated levels of HBsAg in serum or plasma. - Low cost strip format
- Best international prices
- Relative Sensitivity: >99.0%
- Relative Specificity: 98.7%
- Accuracy: 99.8%
|
|
| |
|
| HCVABSC |
 |
Cloning the viral genome has made it possible to develop this serologic assay that uses recombinant antigens to avoid nonspecific cross-reactivity and to increase the sensitivity of the HCV antibody tests. The recombinant HCV proteins used in the test kit are encoded by the genes for both structural (nucleocapsid) and non-structural proteins.
- Attractive cassette format
- Best international prices
- Relative Sensitivity: 99.0%
- Relative Specificity: 98.6%
- Accuracy: 99.3%
- High performance immunoassay technology
- Best technology with full technical support
|
|
| |
|
| HCVABSS |
 |
Cloning the viral genome has made it possible to develop this serologic assay that uses recombinant antigens to avoid nonspecific cross-reactivity and to increase the sensitivity of the HCV antibody tests. The recombinant HCV proteins used in the test kit are encoded by the genes for both structural (nucleocapsid) and non-structural proteins.
- Lowest cost strip format
- Best international prices
- Relative Sensitivity: 99.0%
- Relative Specificity: 98.6%
- Accuracy: 99.3%
|
|
| |
|
| HCVSC |
 |
An easy to use cassette test for Hepatitis C. Clinical pack, for serum or plasma. Immunoassay technology. FDA Approved, more than 99% accurate.
|
|
| |
|
| HCVSS |
 |
An easy to use, inexpensive strip test for Hepatitis C. Clinical pack, for serum or plasma. Immunoassay technology. FDA Approved, more than 99% accurate.
|
|
| |
|
| HIVBC |
 |
Professional use only. The SURESCREEN HIV 1/2 Rapid Test Device (Whole Blood/Serum/ Plasma) is a rapid test to qualitatively detect the presence of antibody to HIV 1 and/or HIV 2 in whole blood, serum or plasma specimen. The test utilizes latex conjugate and multiple recombinant HIV proteins to selectively detect antibodies to the HIV 1/2 in whole blood, serum or plasma.
- Attractive cassette format
- Best international prices
- Relative Sensitivity: 99.9%
- Relative Specificity: 99.6%
- High performance immunoassay technology
- Best technology with full technical support
|
|
| |
|
| HIVBC40 |
 |
Professional use only. The HIV 1/2/O Tri-line Human Immunodeficiency Virus Rapid Test Device (Whole Blood/Serum/Plasma) is the most up to date rapid test to qualitatively detect the presence of antibodies to HIV-1, HIV 2, and/or Subtype O in whole blood, serum or plasma specimen.
- HIV 1/2/O Tri-line
- Attractive cassette format
- Best international prices
- Relative Sensitivity: 99.9% (99.4-100 %)*
- Relative Specificity: 99.8% (99.5-99.9%)*
- Relative Accuracy: 99.8% (99.6-99.9%)* (* 95% Confidence Interval)
- High performance immunoassay technology
- Best technology with full technical support
|
|
| |
|
| MALBC |
 |
The Malaria P.f. Rapid Test Device (Whole Blood) is a rapid chromatographic immunoassay for the qualitative detection of circulating plasmodium falciparum in whole blood, detecting HRP-2.
- Attractive cassette format
- Best international prices
- Relative Sensitivity: >99%
- Relative Specificity: >99%
- Relative accuracy >99%
- High performance immunoassay technology
- Best technology with full technical support
|
|
| |
|
| TBBC |
 |
Our One Step TB is a breakthrough in TB detection. The One Step TB test is a chromatographic immunoassay for the qualitative detection of human anti-TB (M. tuberculosis, M. bovis and M. africanum) antibodies (all isotypes: IgG, IgM, IgA, etc.).
- Attractive cassette format
- Best international prices
- Relative Sensitivity: >99%
- Relative Specificity: >99%
- Relative accuracy >99%
- High performance immunoassay technology
- Best technology with full technical support
|
|